Journal of Chromatography A 1996-10-25

Solid-phase extraction of polar pesticides from environmental water samples on graphitized carbon and Empore-activated carbon disks and on-line coupling to octadecyl-bonded silica analytical columns.

J Slobodník, O Oztezkizan, H Lingeman, U A Brinkman

Index: J. Chromatogr. A. 750(1-2) , 227-38, (1996)

Full Text: HTML

Abstract

The suitability of Empore-activated carbon disks (EACD), Envi-Carb graphitized carbon black (GCB) and CPP-50 graphitized carbon for the trace enrichment of polar pesticides from water samples was studied by means of off-line and on-line solid-phase extraction (SPE). In the off-line procedure, 0.5-2 l samples spiked with a test mixture of oxamyl, methomyl and aldicarb sulfoxide were enriched on EnviCarb SPE cartridges or 47 mm diameter EACD and eluted with dichloromethane-methanol. After evaporation, a sample was injected onto a C18-bonded silica column and analysed by liquid chromatography with ultraviolet (LC-UV) detection. EACD performed better than EnviCarb cartridges in terms of breakthrough volumes (> 2 l for all test analytes), reproducibility (R.S.D. of recoveries, 4-8%, n = 3) and sampling speed (100 ml/min); detection limits in drinking water were 0.05-0.16 microgram/l. In the on-line experiments, 4.6 mm diameter pieces cut from original EACD and stacked onto each other in a 9 mm long precolumn, and EnviCarb and CPP-50 packed in 10 x 2.0 mm I.D. precolumn, were tested, and 50-200 ml spiked water samples were preconcentrated. Because of the peak broadening caused by the strong sorption of the analytes on carbon, the carbon-packed precolumns were eluted by a separate stream of 0.1 ml/min acetonitrile which was mixed with the gradient LC eluent in front of the C18 analytical column. The final on-line procedure was also applied for the less polar propoxur, carbaryl and methiocarb. EnviCarb could not be used due to its poor pressure resistance. CPP-50 provided less peak broadening than EACD: peak widths were 0.1-0.3 min and R.S.D. of peak heights 4-14% (n = 3). In terms of analyte trapping efficiency on-line SPE-LC-UV with a CPP-50 precolumn also showed better performance than when Bondesil C18/OH or polymeric PLRP-S was used, but chromatographic resolution was similar. With the CPP-50-based system, detection limits of the test compounds were 0.05-1 microgram/l in surface water.


Related Compounds

Related Articles:

Effects of exposure to oxamyl, carbofuran, dichlorvos, and lindane on acetylcholinesterase activity in the gills of the Pacific oyster Crassostrea gigas.

2010-08-01

[Environ. Toxicol. 25(4) , 327-32, (2010)]

Relative inhibition of rat plasma and erythrocyte cholinesterases by pesticide combinations.

1991-04-01

[Vet. Hum. Toxicol. 33(2) , 166-8, (1991)]

Differential toxicities of organophosphate and carbamate insecticides in the nestling European starling (Sturnus vulgaris).

2000-08-01

[Arch. Environ. Contam. Toxicol. 39(2) , 233-42, (2000)]

A method to determine precise benchmark doses for carbamate anticholinesterases.

2007-03-01

[Toxicol. Sci. 96(1) , 154-61, (2007)]

Effect of methomyl and oxamyl soil applications on early control of nematodes and insects.

2011-05-01

[Pest Manag. Sci. 67(5) , 507-13, (2011)]

More Articles...