Journal of Separation Science 2008-08-01

Structure and performance of silica-based monolithic HPLC columns.

Stephan Altmaier, Karin Cabrera

Index: J. Sep. Sci. 31(14) , 2551-9, (2008)

Full Text: HTML

Abstract

Silica-based monolithic columns were prepared for HPLC with systematic variations of the tetramethoxysilane (TMOS) and polyethylene oxide (PEO) content as reactants in a sol-gel process accompanied by phase separation. The resulting monoliths showed differences in the macropore and silica skeleton diameter as well as in the corresponding domain sizes (the sum of macropore and skeleton diameter). All monoliths were synthesized with a diameter of 4.6 mm and cladded with a suitable polyaryletheretherketone (PEEK) polymer in a standardized and optimized manner for the subsequent chromatographic evaluation of the resulting monolithic HPLC columns. The columns were tested under normal phase conditions using n-heptane/dioxane (95:5 v/v) as a mobile phase and 2-nitroanisole as a test compound for the determination of separation efficiency and permeability. Two different sets of columns were prepared: the first one in which the amount of PEO was stepwise decreased to yield monoliths with identical macropore volumes and variations in the domain sizes. The second group of materials was synthesized adjusting both TMOS and PEO quantities to yield monolithic columns with identical macropore diameters of about 1.80 microm but different skeleton diameters and macropore volumes. The chromatographic results suggest that an increase in the column performance cannot be achieved by just arbitrarily decreasing the domain size of a given column. From a certain point of "downsizing" the monolithic structure a loss of structural homogeneity can be observed, which is apparently responsible for a lower chromatographic performance.


Related Compounds

Related Articles:

Sol-gel-based silver nanoparticles-doped silica – Polydiphenylamine nanocomposite for micro-solid-phase extraction.

2015-07-30

[Anal. Chim. Acta 886 , 56-65, (2015)]

Resorcinol-formaldehyde xerogel as a micro-solid-phase extraction sorbent for the determination of herbicides in aquatic environmental samples.

2015-07-01

[J. Sep. Sci. 38 , 2305-11, (2015)]

A novel amperometric biosensor based on gold nanoparticles anchored on reduced graphene oxide for sensitive detection of l-lactate tumor biomarker.

2015-07-15

[Biosens. Bioelectron. 69 , 280-6, (2015)]

The sol-gel prepared SiO2-CaO-P2O5 composites doped with Metronidazole for application in local delivery systems.

2012-01-01

[Pharm. Dev. Technol. 17(6) , 697-704, (2012)]

Preparation and evaluation of open tubular C18-silica monolithic microcartridges for preconcentration of peptides by on-line solid phase extraction capillary electrophoresis.

2014-10-10

[Anal. Chim. Acta 846 , 51-9, (2014)]

More Articles...