Journal of Chromatography B 2010-11-15

Development and validation of a gas chromatography/ion trap-mass spectrometry method for simultaneous quantification of cocaine and its metabolites benzoylecgonine and norcocaine: application to the study of cocaine metabolism in human primary cultured renal cells.

Maria João Valente, Félix Carvalho, M Lourdes Bastos, Márcia Carvalho, Paula Guedes de Pinho, Maria João Valente, Félix Carvalho, M. Lourdes Bastos, Márcia Carvalho, Paula Guedes de Pinho

Index: J. Chromatogr. B. Analyt. Technol. Biomed. Life Sci. 878(30) , 3083-8, (2010)

Full Text: HTML

Abstract

Acute renal failure is a common finding in cocaine abusers. While cocaine metabolism may contribute to its nephrotoxic mechanisms, its pharmacokinetics in kidney cells is hitherto to be clarified. Primary cultures of human proximal tubular cells (HPTCs) provide a well-characterized in vitro model, phenotypically representative of HPTCs in vivo. Thus, the present work describes the first sensitive gas chromatography/ion trap-mass spectrometry (GC/IT-MS) method for measurement of cocaine and its metabolites benzoylecgonine (BE) and norcocaine (NCOC) using a primary culture of HPTCs as cellular matrix, following solid phase extraction (SPE) and derivatization with N-methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA). The application of this methodology also enables the identification of two other cocaine metabolites: ecgonine methyl ester (EME) and anhydroecgonine methyl ester (AEME). The validation of the method was performed through the evaluation of selectivity, linearity, precision and accuracy, limit of detection (LOD), and limit of quantification (LOQ). Its applicability was demonstrated through the quantification of cocaine, BE and NCOC in primary cultured HPTCs after incubation, at physiological conditions, with 1 mM cocaine for 72 h. The developed GC/IT-MS method was found to be linear (r² > 0.99). The intra-day precision varied between 3.6% and 13.5% and the values of accuracy between 92.7% and 111.9%. The LOD values for cocaine, BE and NCOC were 0.97±0.09, 0.40±0.04 and 20.89±1.81 ng/mL, respectively, and 3.24±0.30, 1.34±0.14 and 69.62±6.05 ng/mL as LOQ values.Copyright © 2010 Elsevier B.V. All rights reserved.


Related Compounds

Related Articles:

Sensitive method for detection of cocaine and associated analytes by liquid chromatography-tandem mass spectrometry in urine.

2009-10-01

[J. Anal. Toxicol. 33(8) , 447-55, (2009)]

Application of discriminant analysis to differentiate between incorporation of cocaine and its congeners into hair and contamination.

2008-03-21

[Forensic Sci. Int. 176(1) , 13-8, (2008)]

Quantitation of cocaine, benzoylecgonine, cocaethylene, methylecgonine, and norcocaine in human hair by positive ion chemical ionization (PICI) gas chromatography-tandem mass spectrometry.

2000-10-01

[J. Anal. Toxicol. 24(7) , 489-95, (2000)]

Cocaine and its major metabolites in plasma and urine samples from patients in an urban emergency medicine setting.

2000-10-01

[J. Anal. Toxicol. 24(7) , 478-81, (2000)]

The ability of bacterial cocaine esterase to hydrolyze cocaine metabolites and their simultaneous quantification using high-performance liquid chromatography-tandem mass spectrometry.

2011-12-01

[Mol. Pharmacol. 80(6) , 1119-27, (2011)]

More Articles...