European Journal of Pharmaceutical Sciences 2013-01-23

Solubility-pH profiles of some acidic, basic and amphoteric drugs.

Elham Shoghi, Elisabet Fuguet, Elisabeth Bosch, Clara Ràfols

Index: Eur. J. Pharm. Sci. 48(1-2) , 291-300, (2013)

Full Text: HTML

Abstract

The solubility vs. pH profiles of five ionizable drugs of different nature (a monoprotic acid, a monoprotic base, a diprotic base and two amphoteric compounds showing a zwitterionic species each one) have been determined through two different methodologies: the classical shake-flask (S-F) and the potentiometric Cheqsol methods using in both instances the appropriate Henderson-Hasselbalch (H-H) or derived relationships. The results obtained independently from both approaches are consistent. A critical revision about the influence of the electrolyte used as buffering agent in the S-F method on the obtained solubility values is also performed. Thus, some deviations of the experimental points with respect the H-H profiles can be attributed to specific interactions between the buffering electrolyte and the drug due to the hydrotrophic character of citric and lactic acids. In other cases, the observed deviations are independent of the buffers used since they are caused by the formation of new species such as drug aggregates (cefadroxil) or the precipitation of a salt from a cationic species of the analyzed compound (quetiapine).Copyright © 2012 Elsevier B.V. All rights reserved.


Related Compounds

Related Articles:

Development and validation of a stability-indicating LC-UV method for the determination of pantethine and its degradation product based on a forced degradation study.

2014-08-01

[J. Pharm. Biomed. Anal. 97 , 141-50, (2014)]

Development and application of a validated stability-indicating high-performance liquid chromatographic method using photodiode array detection for simultaneous determination of granisetron, methylparaben, propylparaben, sodium benzoate, and their main degradation products in oral pharmaceutical preparations.

2011-01-01

[J. AOAC Int. 94(5) , 1447-60, (2011)]

The EpiOcular Eye Irritation Test (EIT) for hazard identification and labelling of eye irritating chemicals: protocol optimisation for solid materials and the results after extended shipment.

2015-05-01

[Altern. Lab. Anim. 43 , 101-27, (2015)]

Determination and separation of bisphenol A, phthalate metabolites and structural isomers of parabens in human urine with conventional high-pressure liquid chromatography combined with electrospray ionisation tandem mass spectrometry.

2015-03-01

[Anal. Bioanal. Chem 407(9) , 2509-18, (2015)]

Impact of induced fit on ligand binding to the androgen receptor: a multidimensional QSAR study to predict endocrine-disrupting effects of environmental chemicals.

2005-09-08

[J. Med. Chem. 48 , 5666-74, (2005)]

More Articles...