Pharmaceutical Research 2003-09-01

Iontophoretic in vivo transdermal delivery of beta-blockers in hairless rats and reduced skin irritation by liposomal formulation.

Rajkumar Conjeevaram, Ayyappa Chaturvedula, Guru V Betageri, Gangadhar Sunkara, Ajay K Banga

Index: Pharm. Res. 20(9) , 1496-501, (2003)

Full Text: HTML

Abstract

To demonstrate the in vivo transdermal delivery and establish the comparative pharmacokinetics of five beta-blockers in hairless rat.Intravenous dosing was initially done via jugular cannula. For iontophoretic delivery, current (0.1 mA/cm2) was applied for 2 h through a drug reservoir patch containing the beta-blocker (10 mg/ml). Blood samples were collected and analyzed by stereoselective HPLC assays. Any irritation resulting from patch application was quantified by a chromameter. Multilamellar liposomal formulation was prepared by the thin-film hydration method and converted to unilamellar liposomes by extrusion.With transdermal iontophoresis, therapeutically relevant amounts of propranolol (83.78 +/- 7.4 ng/ml) were delivered within an hour and lasted for up to 4 h. Cmax (185.1 +/- 56.8 ng/ml) was reached at hour 3. A significantly higher amount (p < 0.05) of sotalol HCl was delivered compared to other beta-blockers. There was no significant difference in the S/R ratio of AUC0-t for enantiomers after both intravenous and transdermal delivery. Skin irritation was significantly reduced (p < 0.05) when a liposomal formulation of the propranolol base was used rather than the base itself.The comparative pharmacokinetics of intravenous and transdermal iontophoretic delivery of five beta-blockers in hairless rats was established. It was shown that there is no stereoselective permeation.


Related Compounds

Related Articles:

Determination of selected beta-receptor antagonists in biological samples by solid-phase extraction with cholesterolic phase and LC/MS.

2009-01-01

[Anal. Bioanal. Chem 393(1) , 263-72, (2009)]

Quantitative determination of oxprenolol and timolol in urine by capillary zone electrophoresis.

2002-03-08

[J. Chromatogr. A. 949(1-2) , 91-7, (2002)]

High sensitivity analysis of oxprenolol in urine by capillary electrophoresis with C18 packed on-line preconcentrator.

2006-07-24

[J. Chromatogr. B. Analyt. Technol. Biomed. Life Sci. 839(1-2) , 6-11, (2006)]

High frequency controlled capsules with integrated gas producing cells.

2009-05-01

[Eur. J. Pharm. Biopharm. 72(1) , 282-4, (2009)]

Enantiomeric separation by using nano-liquid chromatography with on-column focusing.

2008-08-01

[J. Sep. Sci. 31(14) , 2567-71, (2008)]

More Articles...