Talanta 2011-07-15

Determination of airborne carbonyls via pentafluorophenylhydrazine derivatisation by GC–MS and its comparison with HPLC method

Xiaobing Pang, Alastair C. Lewis, Jacqueline F. Hamilton

Index: Talanta 85(1) , 406-14, (2011)

Full Text: HTML

Abstract

The classical analytical method for gaseous carbonyl measurements based on solid sorbent coated with 2,4-dinitrophenylhydrazine (DNPH) and analysis by HPLC/UV suffers from limited resolution of carbonyls with similar molecular structures and high molecular weights. In this paper, we report the development of a sensitive and reliable analytical method for simultaneous determination of 21 airborne carbonyls within the C(1)-C(9) range. Carbonyls were collected on a sampling tube filled with 100mg Tenax TA (60-80 mesh) sorbent coated with 1 μmol pentafluorophenyl hydrazine (PFPH), followed by solvent desorption and analysis by gas chromatography (GC)/mass spectrometry (MS). Common carbonyl gases including formaldehyde, acetaldehyde, butyraldehyde, hexaldehyde and benzaldehyde at ppbv levels were collected with efficiency greater than 90% onto sampling tubes at a flow rate of 100 mL min(-1). The limits of detection (LODs, signal/noise=3) of the tested carbonyls were in the range of 0.08-0.20 ppbv for a sampled volume of 24.0 L. These limits are less than or comparable with those that can be obtained using the DNPH-HPLC method. The method has been field-tested both in ambient air of York and in diluted cigarette smoke. Comparing field tests with the classical DNPH-HPLC method, good agreement was displayed between the two methods for the same carbonyls, but with more carbonyl species detected by the PFPH-GC/MS method. The PFPH-GC/MS method provides better molecular separation for carbonyls with similar structures, is highly sensitivity and gives confirmation of identification by structures when detected using MS.Copyright © 2011 Elsevier B.V. All rights reserved.


Related Compounds

Related Articles:

Application of pentafluorophenyl hydrazine derivatives to the analysis of nabumetone and testosterone in human plasma by liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry.

2004-12-01

[Anal. Bioanal. Chem 380(7-8) , 891-7, (2004)]

Comparison of extraction methods and detection systems in the gas chromatographic analysis of volatile carbonyl compounds.

1997-08-29

[J. Chromatogr. A. 779(1-2) , 360-9, (1997)]

Carbonyl compounds in gas and particle phases of mainstream cigarette smoke.

2011-11-01

[Sci. Total Environ. 409(23) , 5000-9, (2011)]

Strategy for the identification of key odorants: application to shrimp aroma.

2009-09-04

[J. Chromatogr. A. 1216(36) , 6424-32, (2009)]

Reaction of malondialdehyde-DNA adducts with hydrazines-development of a facile assay for quantification of malondialdehyde equivalents in DNA.

2002-03-01

[Chem. Res. Toxicol. 15(3) , 312-8, (2002)]

More Articles...