O-(2,3,4,5,6-Pentafluorobenzyl)hydroxylamine hydrochloride
Names
[ CAS No. ]:
57981-02-9
[ Name ]:
O-(2,3,4,5,6-Pentafluorobenzyl)hydroxylamine hydrochloride
[Synonym ]:
Hydrogen chloride ethyl 1,2,3,4-tetrahydro-3-isoquinolinecarboxylate (1:1:1)
hydroxylamine, o-((pentafluorophenyl)methyl)-, hydrochloride
O-(2,3,4,5,6-PENTAFLUOROBENZYL)HYDROXYLAMINE HYDROCHLORIDE
3-Isoquinolinecarboxylic acid, 1,2,3,4-tetrahydro-, chloride, ethyl ester, hydrogen salt (1:1)
MFCD00012953
Benzene, 1-[(aminooxy)methyl]-2,3,4,5,6-pentafluoro-, hydrochloride (1:1)
1-[(Aminooxy)methyl]-2,3,4,5,6-pentafluorobenzene hydrochloride (1:1)
EINECS 261-057-7
3-Ethoxycarbonyl-1,2,3,4-tetrahydroisoquinoline hydrochloride
ethyl 1,2,3,4-tetrahydroisoquinoline-3-carboxylate hydrochloride
1,2,3,4-Tetrahydro-isoquinoline-3-carboxylic acid ethyl ester hydrochloride
O-[(2,3,4,5,6-pentafluorophenyl)methyl]hydroxylamine,hydrochloride
Chemical & Physical Properties
[ Boiling Point ]:
214.5ºC at 760mmHg
[ Melting Point ]:
227 °C (subl.)(lit.)
[ Molecular Formula ]:
C12H16ClNO2
[ Molecular Weight ]:
241.714
[ Flash Point ]:
83.5ºC
[ Exact Mass ]:
241.086960
[ PSA ]:
35.25000
[ LogP ]:
3.27470
[ Water Solubility ]:
H2O: 5%, clear
MSDS
Safety Information
[ Personal Protective Equipment ]:
Eyeshields;Gloves;type N95 (US);type P1 (EN143) respirator filter
[ Hazard Codes ]:
Xi
[ Risk Phrases ]:
R36/37/38
[ Safety Phrases ]:
S22-S24/25
[ RIDADR ]:
NONH for all modes of transport
[ WGK Germany ]:
3
[ HS Code ]:
2922199090
Customs
[ HS Code ]: 2922199090
[ Summary ]:
2922199090. other amino-alcohols, other than those containing more than one kind of oxygen function, their ethers and esters; salts thereof. VAT:17.0%. Tax rebate rate:13.0%. . MFN tariff:6.5%. General tariff:30.0%
Articles
Toxicology 314(1) , 1-10, (2013)
Smoking is a major risk factor for atherosclerotic vascular diseases, but the mechanism for its genesis is unknown. We have recently shown that the gas phase of cigarette smoke (nicotine- and tar-free...
Characterisation and calibration of active sampling Solid Phase Microextraction applied to sensitive determination of gaseous carbonyls.Talanta 88 , 252-8, (2012)
A characterisation of a system designed for active sampling of gaseous compounds with Solid Phase Microextraction (SPME) fibres is described. This form of sampling is useful to automate sampling while...
Rapid determination of acetone in human blood by derivatization with pentafluorobenzyl hydroxylamine followed by headspace liquid-phase microextraction and gas chromatography/mass spectrometry.Rapid Commun. Mass Spectrom. 19(5) , 647-53, (2005)
In the current work, a simple, rapid, accurate and inexpensive method was developed for the determination of acetone in human blood. The proposed method is based on derivatization with O-(2,3,4,5,6-pe...