4-phenylpentanoic acid

Modify Date: 2024-01-24 10:21:50

4-phenylpentanoic acid Structure
4-phenylpentanoic acid structure
Common Name 4-phenylpentanoic acid
CAS Number 16433-43-5 Molecular Weight 178.22800
Density 1.066g/cm3 Boiling Point 291.9ºC at 760 mmHg
Molecular Formula C11H14O2 Melting Point 13 °C
MSDS N/A Flash Point 189.1ºC

 Names

Name 4-phenylpentanoic acid
Synonym More Synonyms

 Chemical & Physical Properties

Density 1.066g/cm3
Boiling Point 291.9ºC at 760 mmHg
Melting Point 13 °C
Molecular Formula C11H14O2
Molecular Weight 178.22800
Flash Point 189.1ºC
Exact Mass 178.09900
PSA 37.30000
LogP 2.65490
Vapour Pressure 0.000865mmHg at 25°C
Index of Refraction 1.525

 MSDS


Section1. IDENTIFICATION OF THE SUBSTANCE/MIXTURE
Product identifiers
Product name: 4-PHENYLVALERIC ACID
CAS-No.: 16433-43-5
Relevant identified uses of the substance or mixture and uses advised against
Identified uses: Laboratory chemicals, Manufacture of substances



Section2. HAZARDS IDENTIFICATION
Classification of the substance or mixture
Classification according to Regulation (EC) No 1272/2008 [EU-GHS/CLP]
Skin sensitization (Category 1)
Classification according to EU Directives 67/548/EEC or 1999/45/EC
May cause sensitization by skin contact.
Label elements
Labelling according Regulation (EC) No 1272/2008 [CLP]
Pictogram
Signal wordWarning
Hazard statement(s)
H317May cause an allergic skin reaction.
Precautionary statement(s)
P280Wear protective gloves.
Supplemental Hazardnone
Statements
According to European Directive 67/548/EEC as amended.
Hazard symbol(s)
R-phrase(s)
R43May cause sensitization by skin contact.
S-phrase(s)
S36/37Wear suitable protective clothing and gloves.
Other hazards - none

Section3. COMPOSITION/INFORMATION ON INGREDIENTS
Substances
Formula: C11H14O2
Molecular Weight: 178,23 g/mol
ComponentConcentration
4-PHENYLVALERIC ACID
CAS-No.16433-43-5-

Section4. FIRST AID MEASURES
Description of first aid measures
General advice
Consult a physician. Show this safety data sheet to the doctor in attendance.
If inhaled
If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
In case of skin contact
Wash off with soap and plenty of water. Consult a physician.
In case of eye contact
Flush eyes with water as a precaution.
If swallowed
Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.
Most important symptoms and effects, both acute and delayed
To the best of our knowledge, the chemical, physical, and toxicological properties have not been thoroughly
investigated.
Indication of any immediate medical attention and special treatment needed
no data available

Section5. FIRE-FIGHTING MEASURES
Extinguishing media
Suitable extinguishing media
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Special hazards arising from the substance or mixture
Carbon oxides
Advice for firefighters
Wear self contained breathing apparatus for fire fighting if necessary.
Further information
no data available

Section6. ACCIDENTAL RELEASE MEASURES
Personal precautions, protective equipment and emergency procedures
Use personal protective equipment. Avoid dust formation. Avoid breathing vapors, mist or gas. Ensure
adequate ventilation. Avoid breathing dust.
Environmental precautions
Do not let product enter drains.
Methods and materials for containment and cleaning up
Pick up and arrange disposal without creating dust. Sweep up and shovel. Keep in suitable, closed
containers for disposal.
Reference to other sections
For disposal see section 13.

Section7. HANDLING AND STORAGE
Precautions for safe handling
Avoid contact with skin and eyes. Avoid formation of dust and aerosols.
Provide appropriate exhaust ventilation at places where dust is formed.
Conditions for safe storage, including any incompatibilities
Store in cool place. Keep container tightly closed in a dry and well-ventilated place.
Specific end uses
no data available

Section8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Components with workplace control parameters
Exposure controls
Appropriate engineering controls
Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at
the end of workday.
Personal protective equipment
Eye/face protection
Face shield and safety glasses Use equipment for eye protection tested and approved under
appropriate government standards such as NIOSH (US) or EN 166(EU).
Skin protection
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique
(without touching glove's outer surface) to avoid skin contact with this product. Dispose of
contaminated gloves after use in accordance with applicable laws and good laboratory practices.
Wash and dry hands.
The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the
standard EN 374 derived from it.
Body Protection
Complete suit protecting against chemicals, The type of protective equipment must be selected
according to the concentration and amount of the dangerous substance at the specific workplace.
Respiratory protection
For nuisance exposures use type P95 (US) or type P1 (EU EN 143) particle respirator.For higher
level protection use type OV/AG/P99 (US) or type ABEK-P2 (EU EN 143) respirator cartridges. Use
respirators and components tested and approved under appropriate government standards such as
NIOSH (US) or CEN (EU).

Section9. PHYSICAL AND CHEMICAL PROPERTIES
Information on basic physical and chemical properties
a) AppearanceForm: solid
b) Odourno data available
c) Odour Thresholdno data available
d) pHno data available
e) Melting point/freezingno data available
point
f) Initial boiling point and no data available
boiling range
g) Flash pointno data available
h) Evaporation rateno data available
i) Flammability (solid, gas) no data available
j) Upper/lowerno data available
flammability or
explosive limits
k) Vapour pressureno data available
l) Vapour densityno data available
m) Relative densityno data available
n) Water solubilityno data available
o) Partition coefficient: n- log Pow: 2,738
octanol/water
p) Autoignitionno data available
temperature
q) Decompositionno data available
temperature
r) Viscosityno data available
s) Explosive propertiesno data available
t) Oxidizing propertiesno data available
Other safety information
no data available

Section10. STABILITY AND REACTIVITY
Reactivity
no data available
Chemical stability
no data available
Possibility of hazardous reactions
no data available
Conditions to avoid
no data available
Incompatible materials
Strong oxidizing agents
Hazardous decomposition products
Other decomposition products - no data available

Section11. TOXICOLOGICAL INFORMATION
Information on toxicological effects
Acute toxicity
no data available
Skin corrosion/irritation
no data available
Serious eye damage/eye irritation
no data available
Respiratory or skin sensitization
May cause allergic skin reaction.
Germ cell mutagenicity
no data available
Carcinogenicity
IARC:No component of this product present at levels greater than or equal to 0.1% is identified as
probable, possible or confirmed human carcinogen by IARC.
Reproductive toxicity
no data available
Specific target organ toxicity - single exposure
no data available
Specific target organ toxicity - repeated exposure
no data available
Aspiration hazard
no data available
Potential health effects
InhalationMay be harmful if inhaled. May cause respiratory tract irritation.
IngestionMay be harmful if swallowed.
SkinMay be harmful if absorbed through skin. May cause skin irritation.
EyesMay cause eye irritation.
Signs and Symptoms of Exposure
To the best of our knowledge, the chemical, physical, and toxicological properties have not been thoroughly
investigated.
Additional Information
RTECS: Not available

Section12. ECOLOGICAL INFORMATION
Toxicity
no data available
Persistence and degradability
no data available
Bioaccumulative potential
no data available
Mobility in soil
no data available
Results of PBT and vPvB assessment
no data available
Other adverse effects
no data available

Section13. DISPOSAL CONSIDERATIONS
Waste treatment methods
Product
Offer surplus and non-recyclable solutions to a licensed disposal company. Dissolve or mix the material
with a combustible solvent and burn in a chemical incinerator equipped with an afterburner and scrubber.
Contaminated packaging
Dispose of as unused product.

Section14. TRANSPORT INFORMATION
UN number
ADR/RID: -IMDG: -IATA: -
UN proper shipping name
ADR/RID: Not dangerous goods
IMDG: Not dangerous goods
IATA:Not dangerous goods
Transport hazard class(es)
ADR/RID: -IMDG: -IATA: -
Packaging group
ADR/RID: -IMDG: -IATA: -
Environmental hazards
ADR/RID: noIMDG Marine pollutant: noIATA: no
Special precautions for user
no data available



SECTION 15 - REGULATORY INFORMATION
N/A


SECTION 16 - ADDITIONAL INFORMATION
N/A

 Safety Information

Hazard Codes Xn
HS Code 2916399090

 Customs

HS Code 2916399090
Summary 2916399090 other aromatic monocarboxylic acids, their anhydrides, halides, peroxides, peroxyacids and their derivatives VAT:17.0% Tax rebate rate:9.0% Supervision conditions:none MFN tariff:6.5% General tariff:30.0%

 Synonyms

Pentanoic acid,4-phenyl
4-phenyl-1-pentanoic acid
4-phenyl-pentanoic acid
4-Phenylvaleric acid
Valeric acid,4-phenyl
Top Suppliers:I want be here

Get all suppliers and price by the below link:

4-phenylpentanoic acid suppliers

4-phenylpentanoic acid price