TRICYCLOHEXYLPHOSPHINE [1,3-BIS(2,4,6-TRIMETHYLPHENYL)IMIDAZOL-2-YLIDENE] [3-PHENYL-1H-INDEN-1-YLIDENE] RUTHENIUM (II) DICHLORIDE

Modify Date: 2024-01-11 17:58:09

TRICYCLOHEXYLPHOSPHINE [1,3-BIS(2,4,6-TRIMETHYLPHENYL)IMIDAZOL-2-YLIDENE] [3-PHENYL-1H-INDEN-1-YLIDENE] RUTHENIUM (II) DICHLORIDE Structure
TRICYCLOHEXYLPHOSPHINE [1,3-BIS(2,4,6-TRIMETHYLPHENYL)IMIDAZOL-2-YLIDENE] [3-PHENYL-1H-INDEN-1-YLIDENE] RUTHENIUM (II) DICHLORIDE structure
Common Name TRICYCLOHEXYLPHOSPHINE [1,3-BIS(2,4,6-TRIMETHYLPHENYL)IMIDAZOL-2-YLIDENE] [3-PHENYL-1H-INDEN-1-YLIDENE] RUTHENIUM (II) DICHLORIDE
CAS Number 254972-49-1 Molecular Weight 947.073
Density N/A Boiling Point N/A
Molecular Formula C54H67Cl2N2PRu Melting Point N/A
MSDS USA Flash Point N/A

 Names

Name [1,3-bis(2,4,6-trimethylphenyl)imidazol-2-ylidene]-dichloro-(3-phenylinden-1-ylidene)ruthenium,tricyclohexylphosphane
Synonym More Synonyms

 Chemical & Physical Properties

Molecular Formula C54H67Cl2N2PRu
Molecular Weight 947.073
Exact Mass 946.346252
PSA 23.45000
LogP 16.24680

 MSDS


Section 1: Product Identification
Tricyclohexylphosphine[1,3-bis(2,4,6-trimethylphenyl)imidazol-2-ylidene][3-phenyl-1H-inden-1-ylidene]rutheniu
Chemical Name:
m (II) dichloride, min. 95% [catMETium® RF1]
CAS Registry Number:254972-49-1
Formula:RuCl2[C21H24N2][C15H10][P(C6H11)3]
EINECS Number:none
Chemical Family:organometallic complexes
Synonym:catMETium® IMesPCy

Section 2: Composition and Information on Ingredients
IngredientCAS NumberPercentACGIH (TWA)OSHA (PEL)
Title compound254972-49-1100%no datano data

Section 3: Hazards Identification
Emergency Overview:Irritating to skin, eyes and respiratory tract.
Primary Routes of Exposure:Ingestion, inhalation, skin, eyes
Eye Contact:Causes irritation to eyes
Skin Contact:Causes irritation to skin
Inhalation:Irritating to the nose, mucous membranes and respiratory tract.
Ingestion:No information available on the physiological effects of ingestion. May be harmful if swallowed.
Acute Health Affects:Irritating to skin, eyes and respiratory tract.
Chronic Health Affects:No information on long-term chronic effects.
NTP:No
IARC:No
OSHA:No

SECTION 4: First Aid Measures
Immediately flush the eyes with copious amounts of water for at least 10-15 minutes. A victim may need
Eye Exposure:
assistance in keeping their eye lids open. Get immediate medical attention.
Wash the affected area with water. Remove contaminated clothes if necessary. Seek medical assistance if
Skin Exposure:
irritation persists.
Remove the victim to fresh air. Closely monitor the victim for signs of respiratory problems, such as difficulty
Inhalation:
in breathing, coughing, wheezing, or pain. In such cases seek immediate medical assistance.
Seek medical attention immediately. Keep the victim calm. Give the victim water (only if conscious). Induce
Ingestion:
vomiting only if directed by medical personnel.

SECTION 5: Fire Fighting Measures
Flash Point:none
Autoignition Temperature:none
Explosion Limits:none
Extinguishing Medium:carbon dioxide, dry powder or foam
If this product is involved in a fire, fire fighters should be equipped with a NIOSH approved positive pressure
Special Fire Fighting Procedures:
self-contained breathing apparatus and full protective clothing.
Hazardous Combustion andIf involved in a fire this material may emit irritating organic fumes.
Decomposion Products:
Unusual Fire or Explosion Hazards: No unusual fire or explosion hazards.

SECTION 6: Accidental Release Measures
Small spills can be mixed with vermiculite, sodium carbonate or other suitable non-combustible adsorbent and
Spill and Leak Procedures:
swept up.

SECTION 7: Handling and Storage
Handling and Storage:Store the material in a tightly sealed container in a cool, dry place.

SECTION 8: Exposure Controls and Personal Protection
Eye Protection:Always wear approved safety glasses when handling a chemical substance in the laboratory.
Skin Protection:Wear protective clothing and gloves.
Ventilation:Handle the material in an efficient fume hood.
If ventilation is not available a respirator should be worn. The use of respirators requires a Respirator
Respirator:
Protection Program to be in compliance with 29 CFR 1910.134.
Ventilation:Handle the material in an efficient fume hood.
Additional Protection:No additional protection required.

SECTION 9: Physical and Chemical Properties
Color and Form:orange to brown powder
Molecular Weight:947.07
Melting Point:no data
Boiling Point:no data
Vapor Pressure:no data
Specific Gravity:no data
Odor:not determined
Solubility in Water:insoluble

SECTION 10: Stability and Reactivity
Stability:air and moisture stable
Hazardous Polymerization:no hazardous polymerization
Conditions to Avoid:none
Incompatibility:strong oxidizing agents
Decomposition Products:carbon dioxide, hydrogen chloride, carbon monoxide, organic fumes, phosphorus oxides, ruthenium oxide.

SECTION 11: Toxicological Information
RTECS Data:No information available in the RTECS files.
Carcinogenic Effects:No data
Mutagenic Effects:No data
Tetratogenic Effects:No data

SECTION 12: Ecological Information
Ecological Information:No information available

SECTION 13: Disposal Considerations
Disposal:Dispose of according to local, state and federal regulations.

SECTION 14: Transportation
Shipping Name (CFR):Non-hazardous
Hazard Class (CFR):NA
Additional Hazard Class (CFR):NA
Packaging Group (CFR):NA
UN ID Number (CFR):NA
Shipping Name (IATA):Non-hazardous
Hazard Class (IATA):NA
Additional Hazard Class (IATA):NA
Packaging Group (IATA):NA
UN ID Number (IATA):NA

SECTION 15: Regulatory Information
TSCA:Not listed in the TSCA inventory
SARA (Title 313):Title compound not listed
Second Ingredient:none


SECTION 16 - ADDITIONAL INFORMATION
N/A

 Safety Information

Risk Phrases 36/37/38
Safety Phrases 26-36/37/39

 Synthetic Route

~79%

TRICYCLOHEXYLPHOSPHINE [1,3-BIS(2,4,6-TRIMETHYLPHENYL)IMIDAZOL-2-YLIDENE] [3-PHENYL-1H-INDEN-1-YLIDENE] RUTHENIUM (II) DICHLORIDE Structure

TRICYCLOHEXYLPH...

CAS#:254972-49-1

Literature: Puentener, Kurt; Scalone, Michelangelo Patent: US2006/241156 A1, 2006 ; Location in patent: Page/Page column 6 ;

 Precursor & DownStream

Precursor  2

DownStream  0

 Synonyms

Dichloro(1,3-dimesityl-1,3-dihydro-2H-imidazol-2-ylidene)(3-phenyl-1H-inden-1-ylidene)ruthenium - tricyclohexylphosphine (1:1)
Phosphine, tricyclohexyl-, compd. with dichloro[1,3-dihydro-1,3-bis(2,4,6-trimethylphenyl)-2H-imidazol-2-ylidene](3-phenyl-1H-inden-1-ylidene)ruthenium (1:1)