Chemsuschem Chemistry And Sustainability, Energy & Materials 2013-02-01

Anion-conductive membranes with ultralow vanadium permeability and excellent performance in vanadium flow batteries.

Zhensheng Mai, Huamin Zhang, Hongzhang Zhang, Wanxing Xu, Wenping Wei, Hui Na, Xianfeng Li

Index: ChemSusChem 6(2) , 328-35, (2013)

Full Text: HTML

Abstract

Anion exchange membranes prepared from quaternized poly(tetramethyl diphenyl ether sulfone) (QAPES) were first investigated in the context of vanadium flow battery (VFB) applications. The membranes showed an impressive suppression effect on vanadium ions. The recorded vanadium permeability was 0.02×10(-7)-0.09×10(-7) cm(2) min(-1), which was two orders of magnitude lower than that of Nafion 115. The self-discharge duration of a VFB single cell with a QAPES membrane is four times longer than that of Nafion 115. The morphological difference in hydrophilic domains between QAPES and Nafion was confirmed by TEM. After soaking the membranes in VO(2)(+) solution, adsorbed vanadium ions can barely be found in QAPES, whereas the hydrophilic domains of Nafion were stained. In the ex situ chemical stability test, QAPES showed a high tolerance to VO(2)(+) and remained intact after immersion in VO(2)(+) solution for over 250 h. The performance of a VFB single cell assembled with QAPES membranes is equal to or even better than that of Nafion 115 and remains stable in a long-term cycle test. These results indicate that QAPES membranes can be an ideal option in the fabrication of high-performance VFBs with low electric capacity loss.Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.


Related Compounds

Related Articles:

Thrombocytopenia associated with one type of polysulfone hemodialysis membrane: a report of 5 cases.

2013-01-01

[Am. J. Kidney Dis. 61(1) , 131-3, (2013)]

Heparin-like surface modification of polyethersulfone membrane and its biocompatibility.

2012-11-15

[J. Colloid. Interface Sci. 386(1) , 428-40, (2012)]

Photoresponsive surface molecularly imprinted poly(ether sulfone) microfibers.

2012-09-18

[Langmuir 28(37) , 13284-93, (2012)]

FGF-23 removal is improved by on-line high-efficiency hemodiafiltration compared to conventional high flux hemodialysis.

2013-01-01

[J. Nephrol. 26(2) , 342-9, (2013)]

Bifunctional polyethersulfone hollow fiber with a porous, single-layer skin for use as a bioartificial liver bioreactor.

2012-08-01

[J. Mater. Sci. Mater. Med. 23(8) , 2001-11, (2012)]

More Articles...