Investigative Radiology 2005-04-01

A new polymer concept for coating of vascular stents using PTFEP (poly(bis(trifluoroethoxy)phosphazene) to reduce thrombogenicity and late in-stent stenosis.

Goetz M Richter, Ulrike Stampfl, Sibylle Stampfl, Christoph Rehnitz, Susann Holler, Philip Schnabel, Michael Grunze

Index: Invest. Radiol. 40(4) , 210-8, (2005)

Full Text: HTML

Abstract

We sought to evaluate the new polymer PTFEP (poly(bis(trifluoroethoxy)phosphazene) for (1) its ability to reduce thrombogenicity and late in-stent stenosis and (2) its effect on endothelialization in a rabbit iliac artery model.Nanocoated ( approximately 50 nm) and bare stainless-steel stents were implanted bilaterally in the iliac arteries of 30 New Zealand White rabbits (1, 4, 8, 12, and 16 weeks follow-up) and evaluated by angiography, light, and scanning electron microscopy.Bilateral stent placement was successful in 27 of 30 rabbits. Thrombus depositions occurred in none of the 27 coated but in 4 of the 27 bare stents (P=0.037). A normal angiogram was obtained in 18 of 22 coated stents at risk for restenosis (follow-up >or=4 weeks) but only in 13 of 22 bare stents (P=0.023). Marked restenosis (luminal loss >30%) was found in 6 bare stents (P=0.011) but not in any coated stents. The neointima was 47.7-73.9 mum on coated and 66.9-115.2 mum on bare stents (statistically significant at 4, 8, and 16 weeks). Scanning electron microscopy detected full endothelialization in all stents from 4 weeks on (22 stents in both groups).PTFEP nanocoating successfully showed thromboresistance and reduced late in-stent stenosis. Endothelialization was equal in both stent types. Studies in more human-like models and human feasibility studies in human arteries are encouraged.


Related Compounds

Related Articles:

Properties and clinical development of a novel coating technology: the poly[bis(trifluoroethoxy)phosphazene].

2010-01-01

[Recent Pat. Drug Deliv. Formul. 4(1) , 18-22, (2010)]

The efficacy of nanoscale poly[bis(trifluoroethoxy) phosphazene] (PTFEP) coatings in reducing thrombogenicity and late in-stent stenosis in a porcine coronary artery model.

2007-05-01

[Invest. Radiol. 42(5) , 303-11, (2007)]

Radiation grafting of hydrophilic monomers onto poly[bis(trifluoroethoxy)phosphazene].

1994-09-01

[Biomaterials 15(11) , 937-43, (1994)]

Polyphosphazenes as biomaterials: surface modification of poly(bis(trifluoroethoxy)phosphazene) with polyethylene glycols.

1993-05-01

[Biomaterials 14(6) , 430-6, (1993)]

Arterial distribution characteristics of Embozene particles and comparison with other spherical embolic agents in the porcine acute embolization model.

2009-12-01

[J. Vasc. Interv. Radiol. 20(12) , 1597-607, (2009)]

More Articles...