Steviol
Names
[ CAS No. ]:
471-80-7
[ Name ]:
Steviol
[Synonym ]:
steviol
(5β,8α,9β,10α,13α)-13-Hydroxykaur-16-en-18-oic acid
Stevioside
Hydroxydehydrostevic acid
Steviol hydrate
Biological Activity
[Description]:
[Related Catalog]:
[References]
Chemical & Physical Properties
[ Density]:
1.2±0.1 g/cm3
[ Boiling Point ]:
464.5±45.0 °C at 760 mmHg
[ Melting Point ]:
215°
[ Molecular Formula ]:
C20H30O3
[ Molecular Weight ]:
318.450
[ Flash Point ]:
248.8±25.2 °C
[ Exact Mass ]:
318.219482
[ PSA ]:
57.53000
[ LogP ]:
4.44
[ Vapour Pressure ]:
0.0±2.6 mmHg at 25°C
[ Index of Refraction ]:
1.569
[ Storage condition ]:
2-8C
MSDS
Toxicological Information
CHEMICAL IDENTIFICATION
- RTECS NUMBER :
- NZ8176000
- CHEMICAL NAME :
- Kaur-16-en-18-oic acid, 13-hydroxy-
- CAS REGISTRY NUMBER :
- 471-80-7
- LAST UPDATED :
- 199410
- DATA ITEMS CITED :
- 1
- MOLECULAR FORMULA :
- C20-H30-O3
- MOLECULAR WEIGHT :
- 318.50
HEALTH HAZARD DATA
ACUTE TOXICITY DATA
MUTATION DATA
- TYPE OF TEST :
- Mutation in microorganisms
- TEST SYSTEM :
- Bacteria - Salmonella typhimurium
- DOSE/DURATION :
- 10 gm/L
- REFERENCE :
- PNASA6 Proceedings of the National Academy of Sciences of the United States of America. (National Academy of Sciences, Printing & Pub. Office, 2101 Constitution Ave., Washington, DC 20418) V.1- 1915- Volume(issue)/page/year: 82,2478,1985
Safety Information
[ RIDADR ]:
NONH for all modes of transport
[ RTECS ]:
NZ8176000
Precursor & DownStream
Precursor
DownStream
Articles
J. Chromatogr. A. 1350 , 102-11, (2014)
A high-performance TLC (HPTLC) method was newly developed and validated for analysis of 7 steviol glycosides in 6 different types of food and Stevia formulations. After a minimized one-step sample pre...
Preparation and chromatographic evaluation of a newly designed steviol glycoside modified-silica stationary phase in hydrophilic interaction liquid chromatography and reversed phase liquid chromatography.J. Chromatogr. A. 1388 , 110-8, (2015)
A diterpene glycoside compound, rebaudioside A (commonly abbreviated as RA), was immobilized onto porous silica surface through "thiol-ene" click chemistry strategy. The successful immobilization of t...
Determination of eight artificial sweeteners and common Stevia rebaudiana glycosides in non-alcoholic and alcoholic beverages by reversed-phase liquid chromatography coupled with tandem mass spectrometry.Anal. Bioanal. Chem 407(5) , 1505-12, (2015)
The method for the determination of acesulfame-K, saccharine, cyclamate, aspartame, sucralose, alitame, neohesperidin dihydrochalcone, neotame and five common steviol glycosides (rebaudioside A, rebau...